The paradigm shift in chip implantation technology: From passive treatment to active enhancement
DOI:
https://doi.org/10.61173/dx6zh017Keywords:
Passive treatment, active enhancement, paradigm shiftAbstract
This article systematically reviews the development history of chip implantation technology, from the early medical-oriented passive treatment technology to the modern active enhanced application paradigm shift. By analyzing typical cases such as pacemakers, insulin pumps and cochlear implants, this article deeply and fully expounds the principles of passive medical treatment techniques, the effects to the human life, and limitations of medical treatment techniques. At the same time, this article also explores technological breakthroughs in new applications such as enhanced brain-computer interfaces, memory enhancement, and emotion regulation. By analyzing the difference between passive treatment and modern one, this paper finds that the fundamental reason for the paradigm shift lies in core technologies such as chip miniaturization, neural signal processing, and closed-loop feedback control. Noticeably, they gradually correspond the human’s increasing demands for daily life. Finally, this paper discusses the social impact of paradigm shift and the future development direction of chip implantation technology.
References
[1] Epstein, A.E., et al. “2012 ACCF/AHA/HRS Focused Update Incorporated Into the ACCF/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities.” Journal of the American College of Cardiology, 2013, 61(3), e6- e75.
[2] Tracy, C.M., et al. “2012 ACCF/AHA/HRS Focused Update of the 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities.” Circulation, 2013, 127(3), e283-e352.
[3] Brignole, M., et al. “2018 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy.” European Heart Journal, 2021, 39(1), 1-94
[4] Wise, K. D., et al. “An integrated-circuit approach to extracellular microelectrodes.” IEEE Transactions on Biomedical Engineering, 1970, 17(3), 238-247
[5] Ziaie, B., et al. “A single-channel implantable microstimulator for functional neuromuscular stimulation.” IEEE Transactions on Biomedical Engineering, 1997, 44(10), 909-920
[6] Robinson, D. A. “The electrical properties of metal microelectrodes.” Proceedings of the IEEE, 1968, 56(6), 1065- 1071.
[7] Mercier, P. P., et al. “Energy extraction from the biologic battery in the inner ear.” Nature Biotechnology, 2015, 33(8), 882-887
[8] Mercier, P. P., et al. “Energy extraction from the biologic battery in the inner ear.” Nature Biotechnology, 2015, 33(8), 882-887
[9] Epstein, A. E., et al. “2012 ACCF/AHA/HRS Focused Update Incorporated Into the ACCF/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities.” Journal of the American College of Cardiology, 2013, 61(3), e6- e75
[10] Tracy, C. M., et al. “2012 ACCF/AHA/HRS Focused Update of the 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities.” Circulation, 2013, 127(3), e283-e352.
[11] Brignole, M., et al. “2018 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy.” European Heart Journal, 2021, 39(1), 1-94.
[12] Roger, V. L., et al. “Heart Disease and Stroke Statistics—2012 Update.” Circulation, 2021, 125(1), e2-e220.
[13] Heinemann, L., & Krinelke, L. “Insulin Pump Therapy: What is the Evidence for Using Different Types of Boluses “Journal of Diabetes Science and Technology, 2012, 6(5), 1126- 1141, Figure 2
[14] Weissberg-Benchell, J., et al. “Continuous Subcutaneous Insulin Infusion: A Meta-analysis of Glycemic Control and Dean&Francis Baozhi Ding Quality of Life.” Diabetes Care, 2003, 26(9), 2598-2605.
[15] “Quantifying Cochlear Implant Users” Ability for Speaker Identification using CI Auditory Stimuli, figure 4” PubMed Central, 2019, Sep;2019:3118–3122
[16] Wilson, B. S., et al. “Cochlear implants: Current designs and future possibilities.” Journal of Rehabilitation Research & Development, 2011, 48(6), 695-730.
[17] Geers, A. E., et al.“Early sign language exposure and cochlear implantation benefits.” Pediatrics, 2017, 140(1), e20163489.
[18] Chatterjee, M., et al. “Voice emotion recognition by cochlear-implanted children and normal-hearing children.” Ear and Hearing, 2015, 36(2), 239-248
[19] Farinetti, A., et al. “Cochlear implant complications in children and adults: Systematic review of the literature and meta-analysis.” European Archives of Oto-Rhino-Laryngology, 2017, 74(2), 847-856
[20] Seo, D., et al. “Wireless recording in the peripheral nervous system with ultrasonic neural dust.” Neuron, 2015, 91(3), 529- 539.
[21] Chaudhary, U., et al. “Brain-computer interfaces for communication and rehabilitation.” Nature Reviews Neurology, 2022, 18(2), 101-116.
[22] Deadwyler, S. A., et al. Real-Time Recording and Closed-Loop Stimulation in Nonhuman Primates. Nature Communications, 2018, 9, 5303
[23] Berger, T. W., et al. A Cortical Neural Prosthesis for Restoring and Enhancing Memory. Journal of Neural Engineering, 2011, 8(4), 046017
[24] Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. A jump-start for electroceuticals. Nature, 2013, 496(7444), 159-
[25] Mayberg, H. S., et al. Deep brain stimulation for treatmentresistant depression. Neuron, 2005, 45(5), 651-660
[26] https://media.springernature.com/lw685/springerstatic/image/art%3A10.1038%2Fs41928-022-00753-7/ MediaObjects/41928_2022_753_Fig1_HTML.png
[27] Rogers, J.A., et al. “Convergence of Miniaturization and Wireless Technologies in Next-Gen Medicine.” Science, 2023, 380(6642), eabn2030
Downloads
Published
Issue
Section
License
Copyright (c) 2025 by the authors.

This work is licensed under a Creative Commons Attribution 4.0 International License.