Design of Drive Mechanism for Finger Rehabilitation Robot

Authors

  • Zihan Yi

DOI:

https://doi.org/10.61173/pt3phr88

Keywords:

Drive Mechanism, Finger Rehabilitation Robot, Design

Abstract

The incidence of hand dysfunction caused by factors such as stroke and occupational injuries is increasing, severely impacting patients' daily living abilities. High-repetition training based on Continuous Passive Motion (CPM) theory can promote neuroplasticity; however, traditional manual rehabilitation suffers from issues such as high dependence, high cost, low efficiency, and poor compliance. Robot-assisted training, leveraging its high repetition, precise quantitative assessment, and programmable modes, has become a key direction for enhancing rehabilitation efficacy and reducing the healthcare burden. This paper focuses on three mainstream drive mechanisms: pneumatic drive, rigid linkage drive, and cable-driven drive. The pneumatic drive utilizes pneumatic pressure to deform flexible chambers, offering good compliance and high safety, but suffers from shortcomings such as insufficient control accuracy and slow response. The rigid linkage drive transmits power based on planar linkages, featuring high control accuracy, good ergonomics, and ease of achieving fine movements; however, multiple degrees of freedom lead to complex and bulky structures, affecting wear comfort and compliance. The cable-driven drive transmits power from remote motors via flexible cables, offering advantages such as lightweight design, good compliance, and strong adaptability; some designs utilize differential mechanisms to achieve self-adaptive grasping, but face challenges in friction control, elastic compensation, and efficient bidirectional driving. Analysis and comparison suggest that current designs need to strike a balance between safety, performance, and cost: pneumatic and cable-driven drives offer better compliance and adaptability, while the rigid drive demonstrates more pronounced advantages in precision.

References

[1] Qu Zhijun, Wen Hongyuan, Liu Xiaojun, et al. Structure and control system design of an upper limb rehabilitation robot with micro-torque feedback adaptive coupling motion control. Journal of Mechanical Research and Application, 2021, 34(05): 123-128.

[2] Lei Yufeng, Zhao Guangbiao, Tang Maosheng. Effect of task-oriented training combined with upper limb robot on upper limb function rehabilitation in stroke patients. Medical Theory and Practice, 2021, 34(03): 515-517.

[3] Zhao Lihua, Wang Ailin, Xu Zhenfeng. Current status and influencing factors of home rehabilitation exercise compliance in stroke patients. Medical Theory and Practice, 2020, 33(18): 3110-3112.

[4] Guo Xiaohui, Wang Jing, Xu Guanghua. Recent progress in hand function rehabilitation robot research. Chinese Journal of Rehabilitation Medicine, 2017, 32(02): 235-240.

[5] Guo S, Zhang F, Wei W, et al. Kinematic analysis of a novel exoskeleton finger rehabilitation robot for stroke patients. In: 2014 IEEE International Conference on Mechatronics and Automation. IEEE, 2014: 924-929.

[6] Yang Peng. Research on configuration and control of cabledriven finger rehabilitation training robot. Chongqing University of Technology, 2024.

[7] Qin Chao. Research on flexible hand function rehabilitation robot based on pneumatic drive. Harbin Institute of Technology, 2021.

[8] Wang Daoming, Wang Yakun, Zhang Bin, et al. Development of an active and passive finger rehabilitation robot using pneumatic muscle and magnetorheological damper. Mechanism and Machine Theory, 2019, 147(C).

[9] Wang F, Chen Y, Wang Y, et al. A soft pneumatic glove with multiple rehabilitation postures and assisted grasping modes. Sensors and Actuators A: Physical, 2022, 347: 113978.

[10] Ridremont T, Singh I, Bruzek B, et al. Pneumatically actuated soft robotic hand and wrist exoskeleton for motion assistance in rehabilitation. Actuators, 2024, 13(5): 180-.

[11] Shi Haoran. Research on structure design and control of hand rehabilitation exoskeleton. Yanshan University, 2024.

[12] Li G, Cheng L, Sun N. Design, manipulability analysis and optimization of an index finger exoskeleton for stroke rehabilitation. Mechanism and Machine Theory, 2022, 167: 104526.

[13] Shields B, Main J, Peterson S, et al. An anthropomorphic hand exoskeleton to prevent astronaut hand fatigue during extravehicular activities. IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans, 1997, 27(5): 668-673.

[14] Iqbal J, Tsagarakis N G, Fiorilla A E, et al. A portable rehabilitation device for the hand. In: Proceedings of the 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, Buenos Aires, Argentina, 2010: 3694- 3697.

[15] Carbone G, Gerding E C, Corves B, et al. Design of a two-DOFs driving mechanism for a motion-assisted finger exoskeleton. Applied Sciences-Basel, 2020, 10(7): 1-23.

[16] Ertas I H, Hocaoglu E, Patoglu V. Assiston-finger: An under-actuated finger exoskeleton for robot-assisted tendon therapy. Robotica, 2014, 32(8): 1363-1382.

[17] Yang Peng. Research on configuration and control of cabledriven finger rehabilitation training robot. Chongqing University of Technology, 2024.

[18] Qin Zhuanping, Zhao Zhuangzhuang, Guo Tinghang, et al. Design of a hand rehabilitation robot system based on flexible cable drive. Journal of Tianjin University of Technology and Education, 2025, 35(01): 1-6.

[19] Ouyang Yunxia. Finger motor function rehabilitation training system based on cable drive. Southeast University, 2021.

[20] Dovat L, et al. HandCARE: A cable-actuated rehabilitation system to train hand function after stroke. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2008, 16(6): 582-591.

[21] Lee S W, Landers K A, Park H. Development of a biomimetic hand exotendon device (BiomHED) for restoration of functional hand movement post-stroke. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014, 22(4): 886-898.

Downloads

Published

2025-10-23